Mr. Edward Neugebauer, Jr.
Pro-Mold, Incorporated
Subject: UV Transmittance on one sample.
RECEIVED: One Card Holder identified as; Item MH1UV.
UV/VIS ABSORPTION SPECTROMETRY
Instrument : Perkin Elmer UV/VIS Spectrometer Lambda 25
Scan Wavelength : 190 – 400 nm
Scan Speed : 960 nm/min.
RESULTS:
Sample I.D.
|
@ 358 nm |
@ 369 nm |
@ 374 nm |
@ 383 nm |
MH1UV
|
99.988 % |
99.991 % |
99.987 % |
100 % |
Sample I.D.
|
Up to 385 nm |
@ 386 nm |
MH1UV
|
> 65 |
> 65 |
Ultraviolet light is divided into three major wavelengths: UVA, UVB, and UVC. UVC radiation is completely blocked by the ozone layer with wavelengths from 200 to 290 nm. The UVA and UVB radiation is not completely blocked by the ozone layer. The UVA wavelengths are from 320 to 400 nm and the UVB wavelengths are from 290 to 320 nm.
Melissa A. Martin Scott W. Yates
Sr. Project Technician Assistant Manager– Plastics Testing Division
AKRON RUBBER DEVELOPMENT LABORATORY, INC.
PN# 73427
MM/SWY/sc